NovaForm™ PVC Liner

Sewer and culvert rehabilitation

IPEX Inc.

Ask an Expert

A Durable and Cost-Efficient Option for Sewer and Culvert Rehabilitation

NovaForm™ is a styrene-free, expand-in-place structural liner designed for the rehabilitation of sewers and culverts. With NovaForm™, capturing and treating contaminated curing liquid is a thing of the past. As an engineered thermoplastic, it’s installed using steam, and the only jobsite discharge is water.

Workers installing NovaForm in sewer

product details

Why Use NovaForm PVC Liners?

  • This PVC-based structural liner allows municipalities to repair failing infrastructure quickly while respecting the environment.
  • NovaForm combines long-term strength with flexibility, which allows it to handle some of the most challenging conditions
  • Once NovaForm™ has been expanded and cooled, it is ready for service. Laterals can be quickly reinstated robotically, and the line can be placed back into service the same day – often only four or five hours from start to finish
  • From corroded sanitary sewers to deteriorated corrugated steel pipes in need of structural repair, NovaForm™ PVC Liner is available in sizes 6″ to 36″
  • NovaForm™ offers many benefits including time savings, less disruption to local businesses and traffic, and potential cost savings
NovaForm install

specifications

Inspection Made Easy

Factory made to stringent ASTM F1504 Standards, NovaForm™ leaves the facilities fully manufactured with rigorous QA/QC procedures completed prior to shipping. This allows inspectors to verify the final properties of the liner before it’s installed, rather than cut out coupons for post-installation testing as is required for CIPP. Jobsite inspection is simplified as once the liner is expanded its dimensions are similar to sewer or low-pressure PVC pipe – but with no joints.

Diameter

  • 6” to 36” diameters (150mm to 750mm)
  • Factory-made, quality-controlled and tested to stringent ASTM standards
  • No environmental impact
NovaForm Installation

Benefits of NovaForm

    • Time savings
    • Less disruption to local businesses and traffic
    • Potential cost savings

ASTM Standards

NovaForm™ PVC Liner is manufactured in strict accordance with the ASTM F1504 standard and is third-party certified by CSA and BNQ. These measures ensure a consistent final product for the contractor and the end user.

ASTM F1504 Testing Includes:

    • Pipe Diameters (ASTM D 2122)
    • Wall Thickness (ASTM D 2122)
    • Pipe Flattening
    • Pipe Impact Resistance (ASTM D 2444)
    • Pipe Stiffness (ASTM D 2412)
    • Flexural Properties (ASTM D 790)
    • Extrusion Quality
      • Acetone Immersion (ASTM D 2152)
      • Heat Reversion (ASTM F1057)
Aerial view of Novaform pipe on truck prior to installation on the worksite

resources

Learn more about NovaFormTM PVC Liner

Our resources section covers everything you need to know about NovaFormTM PVC Liner. Take a look at our most popular resources below

Learn More

 

Product Details

This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, marking and packaging.

Material Specification

Basic Materials

The pipe shall be made from PVC compound meeting all the requirements for cell classification 12334 as defined in specification D1784 and with minimum flexural modulus properties, tested as per ASTM Method D790, of 320,000psi (2,200MPa).

Other Requirements

Pipe Flattening

There shall be no evidence of splitting, cracking or breaking when the rounded pipe is tested according to section 11.3 of ASTM F1504.

Pipe Impact Strength

The impact strength of rounded pipe shall not be less than the values in Table 1 when tested in accordance with test method D2444 as referenced in ASTM F1504.

Table 1: Minimum Impact Strength at 73°F (23°C)

Pipe size, in. (mm) Impact strength, ft-lb f (J)

6 (150) 210 (284)

8 (200) 210 (284)

10 (250) 220 (299)

12 (300) 220 (299)

15 (375) 220 (299)

18 (450) 220 (299)

24 (600) 220 (299)

30 (750) 220 (299)

Pipe Stiffness

Values for pipe stiffness for the rounded pipe shall comply with Table 2 when tested in accordance with test method D2412 as referenced in ASTM F1504.

Table 2: Minimum Pipe Stiffness at 5% Deflection

Pipe Size, in. (mm) Pipe Stiffness, psi (kPa)

6 (150) 36 (250)

8 (200) 36 (250)

10 (250) 36 (250)

12 (300) 22 (153)

15 (375) 12 (83)

18 (450) 6 (41)

24 (600) 6 (41)

30 (750) 6 (41)

Extrusion Quality

The extrusion quality of the pipe shall be evaluated by the following test methods:

Acetone Immersion: The pipe shall not flake or disintegrate when tested in accordance with test method D2152 as referenced in ASTM F1504.

Heat Reversion: The extrusion quality of the pipe shall be estimated by heat reversion method in accordance with practice F1057 as referenced in ASTM F1504.

Flexural Properties: The flexural strength and modulus of the pipe shall be tested in accordance with test method D790 as referenced in ASTM F1504.

Dimensions

Rounded Pipe Diameter: The average outside diameter of the formed pipe shall meet requirements in Table 3, +/- 1.0% when tested in accordance with test method D2122 as referenced in ASTM F1504.

Rounded Pipe Wall Thickness: The wall thickness of the formed pipe shall not be less than the values specified in Table 3 when tested in accordance with test method D2122 as referenced in ASTM F1504.

Table 3: Rounded Pipe Dimensions

Nominal Outside Diameter, in. (mm) Minimum Wall Thickness, in. (mm)

6 (150) 0.17 (4.3)

8 (200) 0.23 (5.8)

10 (250) 0.28 (7.3)

12 (300) 0.29 (7.4)

15 (375) 0.30 (7.6)

18 (450) 0.27 (6.8)

24 (600) 0.34 (8.7)

30 (750) 0.43 (10.8)

Workmanship, Finish, and Appearance

The rounded and folded pipes shall be homogeneous throughout and free from visible cracks, holes, foreign inclusions, or other defects. The pipe shall be as uniform as commercially possible in colour, opacity, density and other physical properties.

Product Marking

Pipe shall be clearly marked as follows at intervals of 5ft. (1.5m) or less:

Manufacturer’s name or trademark and code
Nominal outside diameter
The PVC cell classification, for example “12334”
The legend “DR XX FOLDED PVC PIPE”
The designation “Specification ASTM F1504”
Length marker and liner distance label, for example “100FT” (“30.5M”)
Packaging

The full length of the PVC pipe is coiled onto a reel in a continuous length for storage and shipment. The minimum diameter of the reel drum or core shall be 48in (1,219mm).

Quality Assurance

When the product is marked with ASTM F1504 designation, the manufacturer affirms that the product was manufactured, inspected, sampled and tested in accordance with the specification and has been found to meet the requirement of it.

Specifications

Extruded PVC compound

6″ – 30″ diameters (150 mm – 750 mm)

ASTM F1504
ASTM F1947

Gravity (non-pressure) applications such as sanitary and storm sewers or culverts

Find what you need?

Whether you are new to thermoplastic solutions or a long-standing customer, your local Customer Service and in-field Technical Sales Representatives provide the support you need. It's this service that distinguishes IPEX in the marketplace.

Back to top