BlazeMaster® Fire Sprinkler Systems

IPEX USA LLC

Ask an Expert

BlazeMaster® Fire Sprinkler Systems (CPVC)

Superior Performance, Durability and Safety

Developed for use in fire sprinkler systems, BlazeMaster® pipe and fittings are made from post-chlorinated polyvinyl chloride (CPVC) and are fully approved for use in NFPA 13 Light Hazard applications in both new and retrofit construction.

Manufactured with Lubrizol BlazeMaster® CPVC compound in the U.S.A, IPEX pipe and fittings are ideal for wet automatic fire sprinkler systems and offer an outstanding combination of features including simple assembly, lightweight construction, lack of rusting, pitting or scaling, and low friction loss.

Blazemaster CPVC (orange) fire protection group image

A Safe, High-performance Pipe & Fittings

  • Manufactured with Lubrizol BlazeMaster® CPVC compound
  • UL Listed for use in NFPA 13 (light hazard), NFPA 13R, and NFPA 13D occupancies, as well as air plenums
  • Available in 3/4″ through 3″ sizes in 10-foot and 15-foot lengths
  • UL and C-UL Listed; FM, MEA, and LPCB Approved; NSF Certified
  • Exceeds ASTM and other industry standards and meets all major building and mechanical codes requirements.
BlazeMaster Fire Protection (orange) installed in pre built facility

Rigorously Tested for Performance and Quality

With a high flash ignition temperature, low flame spread and smoke development ratings, and a fuel contribution of 0, BlazeMaster® is an ideal choice for fire sprinkler applications.

Developed to meet the stringent requirements on use of combustible pipe in buildings, BlazeMaster® pipe and fittings have been successfully tested to flame temperatures of as high as 1400°F. When subjected to pressure tests run at 400 psi (more than twice the rated pressure) for a period of more than one year, BlazeMaster® systems failed to show signs of weakness or failure.

Specifications

Chlorinated Polyvinyl Chloride (CPVC)

3/4″ – 3″ (20mm – 75mm)

Continuous service of 175psi at 150°F (1207 kPa at 66°C)

  • Concealed and exposed, UL and ULC
  • Listed for use in NFPA 13, 13R, and 13D
  • Light Hazard applications including high rise buildings.
  • FM Approved, NSF certified, and permitted for use in air plenums per NFPA 90A.

Wet and Low-pressure Dry Automatic Fire Sprinkler Systems and Aspirated Smoke Detection