XL 75 GPM Model

IPEX USA LLC

Ask an Expert

XL 75 GPM Model Grease interceptor

Comparably compact, durable, and highly effective Endura® XL75 and XL100 models are both based on Hydromechanical operation offering viable alternatives to traditional large-capacity Gravity Grease Interceptors (GGI). XL units can be installed inside or outside, above or below grade. These units come standard with internal flow control or optional external flow control and no hub or threaded connections. 

PRODUCT DETAILS

Explore the many features and benefits of using Endura® XL Grease Interceptors

learn more

SPECIFICATIONS

Learn more on the certifications and specifications of Endura® XL Grease Interceptors

learn more

Resources

Our resources section covers everything you need to know

learn more

Product Details

The Endura XL75 is offered in different specifications to provide application-specific solutions where added grease capacity is required. Using common components to the larger XL100 models, the XL75 has a smaller footprint and liquid capacity; being designed and approved for applications up to 75GPM flow rate. Installation in heavy traffic areas is possible with the standardly supplied CSA Class ‘S’ rated (up to 20,000lbs.) access covers. Light traffic/pedestrian applications have the alternate option of CSA Class ‘M’ rated (up to 4,000lbs) covers.

Patented Dynamic Inlet Baffle uniquely provides access to integrated flow control in service. When opened offers unrestricted access to the Upstream piping system.

Key design features

  • Polyethylene tank with Polypropylene components to handle fluid temperatures up to 160F
  • 10,000lbs pedestrian, 20,00lbs traffic, or Cast-Iron odor-free access covers available.
  • Dynamic Inlet Baffle for easy cleaning
  • 3 pre-plumbed outlet options (back, left, right exit)
  • Smart Tank Design
    • Manual lifting points
    • Molded in tie-down points
    • Wedge shape for floatation resistance
  • Integrated 4” sample port
  • Riser extensions up to 72”
  • Limited Lifetime Warranty for peace of mind

Specifications

CAPACITIESEndura
XL 75
Endura
XL 100
Endura
XL 150
Part Number4075A04
4075A04M
4075A04C
40100A04
40100A04M
40100A04C
40150A04
40150A04M
40150A04C
US Gallons Per Minute
GPM (L/Sec)
75
(4.74)
100
(6.3)
150
(9.5)
Grease Capacity Actual
(ASME A112.14.3)
† NSF ES 15741
559 lb
(253 kg) †
1058 lb
(480 kg) †
1097 lb
(498 kg)
Average Efficiency% (Ibs)
(ASME A112.14.3)
97%98%96.3%
Operating
Temperature Capabilities
160 ̊F (71 ̊C)160 ̊F
(71 ̊C)
160 ̊F
(71 ̊C)
Cover Load Rating
- CSA B481.0
S 10,000 lb
(4536 kg)


M 2000 lb
(907 kg)


CAST IRON
ASTM A48 30B**
S 10,000 lb
(4536 kg)


M 2000 lb
(907 kg)


CAST IRON
ASTM A48 30B**
S 10,000 lb
(4536 kg)


M 2000 lb
(907 kg)


CAST IRON
ASTM A48 30B**
Unit Weight (Empty233 lb
(106 kg)
283 lb
(128 kg)
283 lb
(128 kg)
Liquid Capacity158 gal
(598 L)
257 gal
(973 L)
257 gal
(973 L)
Connection size
(mechanical joint only)
4”4”4”

Specification:

MATERIAL

  • The body, covers and internal components shall be made of corrosion resistant thermoplastics that can withstand operational temperatures up to 160 degree F. The interceptor body shall be constructed of high density polyethylene.

CONNECTIONS

  • Shall be hub mechanical joint PP end connectors or female NPT
    threaded PP end connectors.

DESIGN FEATURES

  • Access covers shall be Special duty traffic rated Type ‘S’ to support 10,000lbs or Medium duty (light vehicular traffic) rated Type ‘M’ to support 2,000lbs, per CSA B481.0 or Cast iron ASTM A48 30B lids meeting H20 loading standards.
  • Internal features shall be removable or allow access for easy cleaning.
  • Risers shall allow for below grade installations of 75 – 150 GPM interceptors to be extended to grade up, up to a maximum of 72″.
  • A flow control device with integrated air intake shall be provided with the interceptor for external flow control type installations.

EFFICIENCY RATING

  • All interceptors shall be rated to an average efficiency per ASME A112.14.3.
  • The maximum grease capacity of each grease interceptor shall be provided per ASME A112.14.3.

MARKINGS

  • All interceptors shall be marked with the manufacturers name or trademark, model number, rated flows), “inlet” and *outlet*, nominal inlet size, applicable standard designations, access cover load classification, efficiency at the minimum grease capacity per ASME A112.14.3, and flow control model number
    for external flow control type installations.

STANDARDS AND LISTING

  • All interceptors shall be certified to ASME A112.14.3 and have UPC listing.
  • 75 gpm and 100 gpm models are additionally certified to PDI G101.
  • Models with S-rated and M-rated cover load ratings are additionally listed to CSA B481.1

Find what you need?

Whether you are new to thermoplastic solutions or a long-standing customer, your local Customer Service and in-field Technical Sales Representatives provide the support you need. It's this service that distinguishes IPEX in the marketplace.

Back to top